Home > Hardware > Power > Backup UPS >

SU2000LCD1U Tripp Lite by Eaton 120V 2000VA 1600W Double-Conversion Smart Online UPS - 5 Outlets, Card Slot, LCD, USB, DB9, 1U Rack

SU2000LCD1U
 

Not in immediate stock. Direct ship from manufacturer, long lead times may apply due to material shortages

Your Price: $955.65


Mfg. Part:: SU2000LCD1U
quantity:

Overview Technical Specifications Why Choose Us to Buy
 

Double-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss
This 100/120/127V 50/60 Hz on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-3% voltage regulation in on-line and battery modes. Featuring 1600W capacity, 540 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time between on-line and battery modes, the SmartOnline® SU2000LCD1U provides the highest level of AC power protection and battery backup for network equipment in your small- to medium-size data center or computer room.

Individually Controllable Load Banks Let You Access and Control Outlets Remotely
Five NEMA 5-20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely. This UPS is recommended for any application supported by in-rack IT equipment, including servers, switches, phone systems, kiosks and high-end engineering and A/V computer systems.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable internal battery provides 10 minutes of support at half load (800W) and three minutes at full load (1600W), keeping protected equipment operational through power failures. The intelligent battery management system with temperature-compensated charging extends battery life.

ENERGY STAR-Certified Economy Mode Helps You Save Money and Protect the Environment
By meeting strict EPA efficiency guidelines, this ENERGY STAR-certified UPS system helps you save money and energy. A power-saving Economy mode setting option offers enhanced efficiency and reduced BTU output when utility power is already high quality.

Set Output Frequency to Match That of Your Connected Equipment
Using the UPS in Frequency Conversion mode will correct or convert the incoming frequency of 50 Hz to output 60 Hz (and vice versa).

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
The front-panel LCD features eight selectable screens of UPS data (including load, voltage and battery data) and multiple screens of configuration and setup options. LEDs indicate AC output availability and fault status. On-screen operational diagram offers an easy-to-grasp visual representation of on-line, battery and ECO/Bypass modes.

Advanced Communications Ports Allow for Automatic Shutdowns
RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended system shutdown in case of a prolonged power failure. Wireable ports enable EPO (Emergency Power Off) and ROO (Remote Off/On) operation for UPS emergency and daily operation preferences. RS-232 and USB cables are included.

More from the Manufacturer

Power Description
Load Capacity (VA): 2000 VA
Load Capacity (Watt): 1600 W
Input Voltage: 120 V AC
Output Voltage:
  • 100 V AC
  • 120 V AC
  • 127 V AC
  • Output Frequency: 60 Hz
    Waveform Type: Pure Sine Wave
    Surge Energy Rating: 540 J
    Management
    Network Management: SNMP/Web
    Alarm:
  • Power Failure
  • Low Battery
  • Overload
  • UPS Fault
  • UPS StartUp
  • Controls/Indicators
    Status Indicators:

    LED Indicators:

    • AC Output status (green)
    • Shutdown / Fault condition (red)

    Interfaces/Ports
    EPO Port: Yes
    USB (HID Compliant) Port: Yes
    Battery Information
    DC System Voltage: 48 V DC
    Battery Chemistry: Lead Acid
    Backup/Run Time (Full Load): 3 Minute
    Backup/Run Time (Half Load): 10 Minute
    Hot Swappable: Yes
    Typical Battery Recharge Time: 8 Hour
    Replaceable Battery: Yes
    Environmental Conditions
    Maximum Operating Elevation: 9842.52 ft
    Storage Temperature: 5°F (-15°C) - 122°F (50°C)
    Maximum Operating Temperature: 104°F (40°C)
    Sound Emission (A-Weighted): 65 dB(A)
    Thermal Dissipation: 260.45 W
    Physical Characteristics
    Height: 1.7"
    Width: 17.3"
    Depth: 28"
    Rack Height: 1U
    Form Factor: Rack-mountable
    Weight (Approximate): 48.50 lb
    Miscellaneous
    Package Contents:
    • SmartOnline SU2000LCD1U 2000VA Rack-mountable UPS
    • USB Cable
    • RS-232 Cable
    • Rack-Mounting Hardware
    • Owner's Manual

    Energy Star: Yes
    Country of Origin: China
    Environmentally Friendly: Yes
    Environmental Compliance: Restriction of Hazardous Substances (RoHS)
    Warranty
    Limited Warranty: 2 Year
    Key Features


    • Product Description

      Double-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss
      This 100/120/127V 50/60 Hz on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-3% voltage regulation in on-line and battery modes. Featuring 1600W capacity, 540 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time between on-line and battery modes, the SmartOnline® SU2000LCD1U provides the highest level of AC power protection and battery backup for network equipment in your small- to medium-size data center or computer room.

      Individually Controllable Load Banks Let You Access and Control Outlets Remotely
      Five NEMA 5-20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely. This UPS is recommended for any application supported by in-rack IT equipment, including servers, switches, phone systems, kiosks and high-end engineering and A/V computer systems.

      Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
      The field-replaceable, hot-swappable internal battery provides 10 minutes of support at half load (800W) and three minutes at full load (1600W), keeping protected equipment operational through power failures. The intelligent battery management system with temperature-compensated charging extends battery life.

      ENERGY STAR-Certified Economy Mode Helps You Save Money and Protect the Environment
      By meeting strict EPA efficiency guidelines, this ENERGY STAR-certified UPS system helps you save money and energy. A power-saving Economy mode setting option offers enhanced efficiency and reduced BTU output when utility power is already high quality.

      Set Output Frequency to Match That of Your Connected Equipment
      Using the UPS in Frequency Conversion mode will correct or convert the incoming frequency of 50 Hz to output 60 Hz (and vice versa).

      Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
      The front-panel LCD features eight selectable screens of UPS data (including load, voltage and battery data) and multiple screens of configuration and setup options. LEDs indicate AC output availability and fault status. On-screen operational diagram offers an easy-to-grasp visual representation of on-line, battery and ECO/Bypass modes.

      Advanced Communications Ports Allow for Automatic Shutdowns
      RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended system shutdown in case of a prolonged power failure. Wireable ports enable EPO (Emergency Power Off) and ROO (Remote Off/On) operation for UPS emergency and daily operation preferences. RS-232 and USB cables are included.

      More from the Manufacturer


    • Plug/Connector Type: NEMA 5-20P
    • Receptacle Type: NEMA 5-15/20R
    • Receptacle Detail: 5 x NEMA 5-15/20R
    • Dataline Protection: RS-232
    • Transfer Time: 0 ns
    • EMI/RFI Noise Filter: Yes
    • Phase: Single Phase
    • Application/Usage: Network Equipment, Server, Network Closet, Computer Room, IT Equipment, Switch, Phone, Kiosk, High-end System
    • Load Capacity (VA): 2000 VA
    • Load Capacity (Watt): 1600 W
    • Input Voltage: 120 V AC
    • Output Voltage: 100 V AC, 120 V AC, 127 V AC
    • Output Frequency: 60 Hz
    • Waveform Type: Pure Sine Wave
    • Surge Energy Rating: 540 J
    • Network Management: SNMP/Web
    • Alarm: Power Failure, Low Battery, Overload, UPS Fault, UPS StartUp
    • Status Indicators:

      LED Indicators:

        AC Output status (green), Shutdown / Fault condition (red),
    • EPO Port: Yes
    • USB (HID Compliant) Port: Yes
    • DC System Voltage: 48 V DC
    • Battery Chemistry: Lead Acid
    • Backup/Run Time (Full Load): 3 Minute
    • Backup/Run Time (Half Load): 10 Minute
    • Hot Swappable: Yes
    • Typical Battery Recharge Time: 8 Hour
    • Replaceable Battery: Yes
    • Maximum Operating Elevation: 9842.52 ft
    • Storage Temperature: 5°F (-15°C) - 122°F (50°C)
    • Maximum Operating Temperature: 104°F (40°C)
    • Sound Emission (A-Weighted): 65 dB(A)
    • Thermal Dissipation: 260.45 W
    • Height: 1.7"
    • Width: 17.3"
    • Depth: 28"
    • Rack Height: 1U
    • Form Factor: Rack-mountable
    • Weight (Approximate): 48.50 lb
    • Package Contents:
        SmartOnline SU2000LCD1U 2000VA Rack-mountable UPS, USB Cable, RS-232 Cable, Rack-Mounting Hardware, Owner's Manual,
    • Energy Star: Yes
    • Country of Origin: China
    • Environmentally Friendly: Yes
    • Environmental Compliance: Restriction of Hazardous Substances (RoHS)
    • Limited Warranty: 2 Year

    Share your knowledge of this product with other customers... Write a review

    Browse for more products in the same category as this item:

    Hardware > Power > Backup UPS
    Hardware > Power
    Industries > Government
    Featured Brands > Tripp Lite