2U Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode, the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment. With the included 2U step-down transformer, this 3kVA UPS system can support both low- and high-voltage equipment. Set Power Strategies to Reflect Your Protection Priorities Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency, Max Quality, Frequency Regulation and Auto Adaptive, which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor. Individually Controllable Load Banks Let You Access and Control Outlets Remotely The UPS and transformer combined feature 20 outlets in total-12 unswitched NEMA 5-15/20R on the transformer, six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely. Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable, hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports "smart" external battery packs, such as Tripp Lite's BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life. Automatic Bypass Maintains Utility Output During Fault Conditions Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions. Automatically Turns Back On When Power Is Restored Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status. Advanced Communications Ports Allow for Automatic Saves and Shutdowns RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.
-
General Information Manufacturer: Tripp Lite by Eaton Manufacturer Part Number: SU3000LCD2UHVTF Manufacturer Website Address: https://tripplite.eaton.com/ Brand Name: Tripp Lite by Eaton Product Line: SmartOnline Product Model: SU3000LCD2UHVTF Product Name: SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS Marketing Information: 2U Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode, the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment. With the included 2U step-down transformer, this 3kVA UPS system can support both low- and high-voltage equipment. Set Power Strategies to Reflect Your Protection Priorities Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency, Max Quality, Frequency Regulation and Auto Adaptive, which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor. Individually Controllable Load Banks Let You Access and Control Outlets Remotely The UPS and transformer combined feature 20 outlets in total-12 unswitched NEMA 5-15/20R on the transformer, six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely. Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable, hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports "smart" external battery packs, such as Tripp Lite's BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life. Automatic Bypass Maintains Utility Output During Fault Conditions Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions. Automatically Turns Back On When Power Is Restored Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status. Advanced Communications Ports Allow for Automatic Saves and Shutdowns RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included. Product Type: Double Conversion Online UPS Technical Information Plug/Connector Type: NEMA L6-20P Receptacle Type: - NEMA 5-15/20R
- NEMA 6-15/20R
- NEMA L6-20R
Receptacle Detail: - 12 x NEMA 5-15/20R
- 6 x NEMA 6-15/20R
- 2 x NEMA L6-20R
Transfer Time: 0 ns EMI/RFI Noise Filter: Yes Phase: Single Phase Energy Saving: High Efficiency Economy Mode Operation; Individually Controllable Load Banks Application/Usage: - Mission Critical Equipment
- Server
- Network Equipment
- Data Center
- Computer Room
- Network Closet
Power Description Load Capacity (VA): 3000 VA Load Capacity (Watt): 2700 W Input Voltage: 230 V AC Output Voltage: - 120 V AC
- 208 V AC
Output Frequency: 60 Hz Waveform Type: Pure Sine Wave Surge Energy Rating: 570 J Management Network Management: SNMP/DB9/USB Alarm: - Power Failure
- Low Battery
- Overload
- Fault
Controls/Indicators Status Indicators: 4 Front Panel LEDs: - AC Input (Green)
- AC Output (Green)
- Battery (Yellow)
- Fault (Red)
Interfaces/Ports Serial Port: Yes EPO Port: Yes USB (HID Compliant) Port: Yes Battery Information DC System Voltage: 72 V DC Backup/Run Time (Full Load): 5 Minute Backup/Run Time (Half Load): 13.50 Minute Hot Swappable: Yes Typical Battery Recharge Time: 3 Hour Replaceable Battery: Yes Environmental Conditions Maximum Operating Elevation: 9842.52 ft Storage Temperature: 5°F (-15°C) - 122°F (50°C) Maximum Operating Temperature: 104°F (40°C) Thermal Dissipation: 273.44 W Physical Characteristics Height: 7" Width: 17.3" Depth: 24.3" Rack Height: 4U Form Factor: Rack/Tower Weight (Approximate): 133.82 lb Miscellaneous Package Contents: - SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS
- SU5000XFMRT2U20 2U 208V to 120V Step-Down Isolation Transformer
- USB Cable
- DB9 Cable
- EPO Cable
- Rack-mounting Hardware
- Owner's Manual
Country of Origin: China Environmentally Friendly: Yes Environmental Compliance: Restriction of Hazardous Substances (RoHS) Warranty Limited Warranty: 2 Year
Dedicated account managers are available to assist you with purchasing and presales questions at 877-712-2230 Monday through Friday 8-5pm. What Forms Of Payment Do We Take?We accept all forms of payment including Visa, Mastercard, American Express, Discover, Wire Transfer, and Check in Advance. Purchase orders are accepted and net terms are given based on a credit check. Why Buy From ITO?ITO Solutions, Inc. purpose is to provide you, our client, with best in class technology solutions to help you run your network efficiently by leveraging our integrity, partnerships, and years of experience within the IT industry. Our account managers are here to answer your questions and provide you with solutions very effectively.
|
|
|
|
|
|
|
|
|
|
|
|
|
Key Features
Product Description
2U Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode, the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment. With the included 2U step-down transformer, this 3kVA UPS system can support both low- and high-voltage equipment. Set Power Strategies to Reflect Your Protection Priorities Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency, Max Quality, Frequency Regulation and Auto Adaptive, which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor. Individually Controllable Load Banks Let You Access and Control Outlets Remotely The UPS and transformer combined feature 20 outlets in total-12 unswitched NEMA 5-15/20R on the transformer, six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely. Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable, hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports "smart" external battery packs, such as Tripp Lite's BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life. Automatic Bypass Maintains Utility Output During Fault Conditions Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions. Automatically Turns Back On When Power Is Restored Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status. Advanced Communications Ports Allow for Automatic Saves and Shutdowns RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.
- Plug/Connector Type: NEMA L6-20P
- Receptacle Type: NEMA 5-15/20R, NEMA 6-15/20R, NEMA L6-20R
- Receptacle Detail: 12 x NEMA 5-15/20R, 6 x NEMA 6-15/20R, 2 x NEMA L6-20R
- Transfer Time: 0 ns
- EMI/RFI Noise Filter: Yes
- Phase: Single Phase
- Energy Saving: High Efficiency Economy Mode Operation; Individually Controllable Load Banks
- Application/Usage: Mission Critical Equipment, Server, Network Equipment, Data Center, Computer Room, Network Closet
- Load Capacity (VA): 3000 VA
- Load Capacity (Watt): 2700 W
- Input Voltage: 230 V AC
- Output Voltage: 120 V AC, 208 V AC
- Output Frequency: 60 Hz
- Waveform Type: Pure Sine Wave
- Surge Energy Rating: 570 J
- Network Management: SNMP/DB9/USB
- Alarm: Power Failure, Low Battery, Overload, Fault
- Status Indicators:
4 Front Panel LEDs: AC Input (Green), AC Output (Green), Battery (Yellow), Fault (Red), - Serial Port: Yes
- EPO Port: Yes
- USB (HID Compliant) Port: Yes
- DC System Voltage: 72 V DC
- Backup/Run Time (Full Load): 5 Minute
- Backup/Run Time (Half Load): 13.50 Minute
- Hot Swappable: Yes
- Typical Battery Recharge Time: 3 Hour
- Replaceable Battery: Yes
- Maximum Operating Elevation: 9842.52 ft
- Storage Temperature: 5°F (-15°C) - 122°F (50°C)
- Maximum Operating Temperature: 104°F (40°C)
- Thermal Dissipation: 273.44 W
- Height: 7"
- Width: 17.3"
- Depth: 24.3"
- Rack Height: 4U
- Form Factor: Rack/Tower
- Weight (Approximate): 133.82 lb
- Package Contents:
SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS, SU5000XFMRT2U20 2U 208V to 120V Step-Down Isolation Transformer, USB Cable, DB9 Cable, EPO Cable, Rack-mounting Hardware, Owner's Manual, - Country of Origin: China
- Environmentally Friendly: Yes
- Environmental Compliance: Restriction of Hazardous Substances (RoHS)
- Limited Warranty: 2 Year
|
|
|
|
|
|
|